PULSO Loading 3D model… 3D view isn't available on this device; showing the image instead.
Drag to rotate · click, then scroll to zoom

Design challenges

  1. Isolating 1 Hz to 300 kHz signals without amplitude or phase distortion: a linear optocoupler and an isolated supply.
  2. User safety: output current held below 10 µApp, whatever the input signal.
  3. A clean analog chain: low-noise rails and separation from the digital and power sections.

Key components

AD9837DDS signal generator
MAX262 · LTC1264Programmable active filter
AD8338 · LMH6505Variable-gain amplifier
IL300 · NXE2S0505Signal and power isolation